Flurine®PC Series Fluoroelastomer FLUORINE
Flurine®PC Series Fluoroelastomer  FLUORINE
Model
Fluorine®PC Series Fluoroelastomer

Item specifics

Features
Peroxide vulcanization. Short second cure time. Hi
Uses
Shaft seals, oil seals, gaskets, O-rings. Extrusion or calendering
Forms
White or light-yellow flake

Review

Description

Flurine®PC series is peroxide-cured fluoroelastomer, copolymerized with vinylidene fluoride (VF2), hexafluoropropylene (HFP), and bromine-containing or iodine-containing fluoroolefin monomers. Usually used in automotive, hydraulic applications, electrical and chemical industries. It has excellent processability and mechanical properties, excellent resistance to high-temperature steam. In addition, only a very short curing time is required.

General

Features

Peroxide vulcanization. Short second cure time. High liquidity

Uses

Shaft seals, oil seals, gaskets, O-rings. Extrusion or calendering

Forms

White or light-yellow flake

Items

Typical Value

Test Method

P228

Physical Properties

Fluorine Contentmass%

66

 

Densityg/cc

1.78~1.84

ASTM D297

Mooney Viscosity

20~45

ASTM D1646 ML 1+10 at 121°C

Water content

0.15

ASTM D 5668

Vulcanization Properties

T10(s)

<60

ASTM D5289

T90(s)

<240

ASTM D5289

Mechanical Properties

Tensile strengthMPa

16

ASTM D412 Method A

100% Modulus

5.0

ASTM D412 Method A

Elongation at Break%

200

ASTM D412 Method A

Tearing StrengthKN/m

22

ASTM D624

Hardness, Shore A

73

ASTM D2240, Type A

Compression Set

38

ASTM D395, Test B 70 hours at 200℃

Air-oven aging

ISO 188 After Dry Heat Aging;70 hours at 230℃

Tensile strength change rate%

-20

ASTM D412 Method A

Elongation at Break change rate(%)

-20

ASTM D412 Method A

Hardness change, Shore A

2

ASTM D2240, Type A 

Thermal Properties

Glass Transition Temp, Tg(℃)

-20

ASTM D1329

Brittleness Temperature(℃)

-30

ASTM D2137

Chemical resistance Properties

Resistance to liquids

3 # standard oil

Volume change rate(%)

+10

ASTM D471 72 hours at 150℃

Mass change rate(%)

+2

ASTM D471 72 hours at 150℃

Formulation

Curing condition

Polymer            100       

MT carbon black,N990    30

DPB25(45%)      3.0 

TAIC(70%)      4.3

HT290             0.5

Press

Oven

6min at 177°C,0.5°

4h at 230°C


1)Store and use all fluoroelastomers only in a well-ventilated area.

2)Do not smoke in areas contaminated with dust from fluoroelastomers.

3)Avoid eye contact. After handling fluoroelastomers wash any skin that came in contact with the product with soap and water.

4)Potential hazards, including evolution of toxic vapors, exist during compounding or processing under high temperatures. 

5)Before processing the fluoroelastomers, read and consult the MSDS, and follow all label directions and operation cautions.

1)Fluoroelastomers be packed in PVC bags in the shape of rubber film, each bag weight 5KGS, and finally be put into a carton. Each carton contains 5 bags with net weight 25KGS.

2)It must be stored in a clean, cool, and dry place. The storage life is one year from the date of production. It must be re-inspected if over one year and only can use if qualified.

3)It is transported as non-dangerous chemicals. Avoid excessive vibration and far away from pollution, sunshine and water during the transport.